Search results for "power supply"
showing 10 items of 38 documents
Robust model-following control of parallel UPS single-phase inverters
2008
This paper presents a robust control technique applied to modular uninterruptible power-supply (UPS) inverters operating in parallel. When compared to conventional proportional-integral (PI) control, the proposed technique improves the response of the output voltage to load steps and to high distorted output currents, reducing the distortion of the output voltage. Furthermore, an excellent distribution of currents between modules is achieved, resulting in fine power equalization between the inverters on stream. The crossover frequency of the different loop gains involved is moderate, so that robustness to variations of the operation point and to modeling uncertainties is achieved. A compara…
Uncertainty evaluation in the measurements for the electric power quality analysis
2013
The paper deals with the uncertainty estimation in the measurements performed to assess the electric power quality. In a first steps, according to the 'ISO - Guide to Expression of the Uncertainty in Measurements' all the error sources, which give a significant contribution to the combined uncertainty associated to the measurement results, are identified. Successively, in order to analyze how the errors propagate through the measurement chain, a Monte Carlo based approach is proposed. The method exploits an ad-hoc developed simulator of the measurement process, which takes into account the particular way of propagation of all the identified error sources. Eventually, with the aim of validat…
Electric Power Quality Evaluation in the Presence of Electromagnetic Emissions
2013
The measurements for the assessment of the electric power quality are often carried out in hostile electromagnetic environments. The aim of the paper is analyzing if and how both radiated and conducted electromagnetic emissions can disturb the measurement system used to quantify these disturbances. To achieve the target, an experimental approach is proposed, which, by means of a simple and fast test, allows establishing if the real electromagnetic environment, where power quality analysis is performed, can alter the measurements. © 2013 IEEE.
New Power Conditioning System for Battery-free Satellite Buses with Maximum Power Point Tracking
2007
The purpose of this paper is describe a new conception of Power Conditioning Unit (PCU) developed to fulfill the requirements of BepiColombo Electronic Propulsion module. This load bus has very tough specification especially regarding transient response during total load switch-off ("beam out") which has to be less than 2% of the bus voltage. The conception we propose, is the new Sequential Switching Shunt Maximum Power Regulator (S3MPR) consisting in a S3R, to keep the SA voltage at its Maximum Power Point (MPP) followed by a Boost regulator to produce a constant 100V to supply the Electronic Propulsion (EP). This concept may also be of interest for other future missions involving high pow…
Optimized design of high power density EMI filters for power electronic converters
2016
Nowadays, power density of power converters and related EMI filters is gaining more and more attention. This severely impacts on the design constraints in several application domains. A conventional design of the EMI filter does not guarantee the selection of components/configuration leading to the best power density. For this reason, an optimized design procedure of discrete EMI filters in terms of power density is proposed in this paper. It is based on a previously developed rule-based design procedure, introducing here additional features to obtain a more effective optimization of EMI filter's power density. The proposed approach has been validated in terms of EMI filter's performance an…
Medium Voltage Smart Grid: Experimental Analysis of Secondary Substation Narrow Band Power Line Communication
2013
This paper is focused on the possibility of employing narrow band power line communication (PLC) in medium voltage (MV) distribution networks. The topic is investigated by means of both simulations and experimental tests, which were carried out in the distribution network of Ustica Island. In detail, a two-way MV communication was tested between two secondary substations connected by an MV cable power line. Each substation has a by-pass connection at MV bus-bars and an MV/LV oil filled power transformer. In this paper, the MV and the PLC systems under test are described and the experimental tests are presented, which were carried out to evaluate the parameters of the simulation model. The a…
Dynamic performance enhancement of AC/DC PFC boost converters by means of MRAS observers
2015
Controlling a Power Factor Corrected (PFC) boost converter is not a trivial task, because the higher the dynamic performance, the higher is the input current distortion. On the other hand, recent applications of these converters require fast transients in response to disturbances, such as sudden variations of load power, reference voltage and input voltage. Better performance can be obtained adding a feedforward action to the traditional control scheme, using observers to estimate the input voltage and the output current. However, the actual improvement depends on the dynamic performance of the chosen observers. This paper aims at evaluating the applicability and the performance of differen…
Comparison of power quality impact of different photovoltaic inverters- the viewpoint of the grid
2005
This paper presents the results of an experimental analysis performed with the aim of evaluating the effect of many photovoltaic plants on power quality of the grid. Several parameters as voltage and current distortion, flicker, voltage variations at fundamental frequency and power factor have been observed. The measured values have been compared with the limits reported in the standards and, when possibiIe, their dependence on the characteristics of the grid in terms of its impedance has been pointed out.
Soft switched interleaved boost converters used as high-power battery discharge regulator for space power systems
2004
In the following years the telecommunication satellites will have a much greater power demand than nowadays. One reason for this is that the geostationary orbit required by this kind of satellites is becoming too crowded. Probably power levels of l0 kW to l00 kW will be the standard and with life duration of 25 years. It is not possible to keep 0.5 kW modules with more than 100 in parallel and therefore higher power modules (5 kW) must be used. A higher bus voltage seems also necessary and keeping a safety limit of 150 V, any voltage below it and above 100 V could meet the needs. In this paper we will propose a topology that fits the application: two soft switched interleaved boost converte…
Controlled Fault-Tolerant Power Converters for Power Quality Enhancement
2013
Power quality depends generally on the interaction of electrical power with electrical equipments. If electrical equipments operate correctly and reliably without being damaged or stressed, a suitable level of power quality is assured. On the other hand, if the electrical equipment malfunctions, is unreliable, or is damaged during normal usage, power quality is poor and probably the economical loss could be important like the technical one. In the scenario of the Distributed Generation, power quality issues will be moreover important because an higher dissemination of power conditioning equipment will be requested and this obviously increases the sources of vulnerability of the electrical s…